Two-component epoxy-acrylate resin based anchoring adhesive, styrene and solvent free
- rapid curing
- Applicable with conventional spray guns
- High load capacity
APPLICATIONS :
As a fast-curing adhesive for all types of :
- Round corrugated sheet
- threaded rods
- Special bolts and fastening systems.
- Concrete (cracked and uncracked)
- Solid brick factory
- Steel
Before application, the adhesion behaviour or other problems with the substrate such as staining or discolouration must be checked by means of a test. This is due to the different strength, composition and porosity of substrates such as :
- Natural stone
- solid rock
BENEFITS :
- rapid curing
- Applicable with conventional spray guns
- High load capacity
- ATE to ETAG 001 for dowels in concrete
- ETA according to ETAG 001 for busbar connection
- Suitable for cracked concrete
- LEED
- Does not hang down, applicable even on the ceiling
- styrene-free
- a low odour
- Low material loss
PACKAGING :
- Cartridges of 300 ml
COLOUR :
- Component A: white
- Component B: black
- Component A+B mixed: light grey
Conservation :
15 months from the date of manufacture
All Sika AnchorFix®-2 Normal cartridges have an expiry date printed on the label.
Storage conditions :
Properly stored in its original, well-sealed and undamaged packaging, in a cool, dry place at temperatures
between +5ºC and +25ºC. Out of direct sunlight.
Density :
~1,62–1,70 kg/l (component A) | |
~1,44–1,50 kg/l (component B) | |
~1,60–1,68 kg/l (component A+B mixed) |
Mixing ratio
Component A : Component B = 10 : 1 by volume
Layer thickness
~5 mm max.
Thixotropy
Does not sag, even when applied to the ceiling
Product temperature
Sika AnchorFix®-2 Normal should be applied at temperatures between +5°C and 30°C.
Ambient temperature
–5 °C min. / +35 °C maxi.
Dew point
Beware of condensation!
The ambient temperature during application must be at least 3°C above the dew point.
Support temperature
–5 °C min. / +35 °C maxi.
Curing time
Temperature | Open time – gel T | Curing time- T cur |
+25 °C – +30 °C | 4 minutes | 40 minutes |
+20 °C – +25 °C | 5 minutes | 50 minutes |
+15 °C – +20 °C | 6 minutes | 75 minutes |
+10 °C – +15 °C | 8 minutes | 85 minutes |
+5 °C – +10 °C | 10 minutes | 145 minutes |